※ Three boxes of equipment are divided into three parts: high temperature zone, low temperature zone and test zone. The test products are placed in the test zone. The temperature of the high temperature zone or the low temperature zone is impacted into the test zone during impact, and the test product is static.
※ It adopts touch-type graphic control operation interface, which is easy to operate.
※ Impact mode Apply the air path switching method to introduce the temperature into the test area and do the thermal shock test.
※ When high temperature impact or low temperature impact, the maximum time can reach 999H, and the maximum cycle time can reach 9999 times.
※ The system can be used for automatic cycle or manual selective shock and can set the three-zone impact and cold flushing.
※ Cooling and adopting binary refrigeration system, the cooling effect is fast, and the cooling method is water-cooled.
※ Three boxes can test the impact normal temperature,
※ High and low temperature conversion time: within 10 seconds (other requirements are agreed)
※ Execution meets the standards and test methods: GJB150.5 temperature impact test; GJB360.7 temperature impact test; GB/2423.22 temperature impact test
model | WBE-LR3-49L | WBE-LR3-80L | WBE-LR3-150L | WBE-LR3-250L | WBE-LR3-335L | ||||||||||
Internal size WxDxH (cm) | 35×35×40 | 40×40×50 | 60×50×50 | 70×60×60 | 80×60×70 | ||||||||||
External dimensions WxDxH (cm) | 147x159x172 | 152X169X182 | 170x184X182 | 180x194X192 | 190x194x210 | ||||||||||
Laboratory temperature range °C | 150℃~ABC | 150℃~ABC | 150℃~ABC | 150℃~ABC | 150℃~ABC | ||||||||||
A -40 | B -55 | C-65 | A -40 | B -55 | C-65 | A -40 | B -55 | C-65 | A -45 | B -55 | C-65 | A -40 | B -55 | C-65 | |
Installed power KW (not power consumption) | 18 | 20 | 22 | 20 | 22 | 24 | 30 | 35 | 38 | 42 | 45 | 48 | 50 | 55 | 60 |
Air-cooled/water-cooled | Air-cooled | Air-cooled | water-cooled | Air-cooled | Water cooling (consider that the water is frozen when the tower is installed outdoors, the equipment cannot be operated when it is frozen; in this case, the chiller can be selected) | ||||||||||
Heating temperature (heat storage zone) °C | 60℃~200℃ | ||||||||||||||
Cooling temperature (cool storage zone) °C | A:-10℃~ -55℃ B:-10℃~ -70℃ C:-10℃~ -75℃ | ||||||||||||||
Heating time (heat storage area) min | RT~200°C is about ≤35min | ||||||||||||||
Cooling time (cold storage area) min | A:+20~ -55℃About need60min B:+20~ -70℃About need≤70min C:+20~ -75℃About need85min | ||||||||||||||
Ambient temperature | Air-cooled ambient temperature requirement -5~ +28℃ Water cooling environment temperature requirement +5~ +35℃ | ||||||||||||||
Weight (approximately) | 700Kg | 900Kg | 1200Kg | 1400Kg | 1900Kg | ||||||||||
Temperature recovery time | Within 5 minutes | ||||||||||||||
High temperature exposure for 30 minutes | |||||||||||||||
Low temperature exposure for 30 minutes | |||||||||||||||
Temperature control accuracy | ±0.5℃ | ||||||||||||||
Evenness | ±2.0℃ | ||||||||||||||
Internal and external materials | Steel plate electrostatic spraying surface treatment or SUS 304 stainless steel | ||||||||||||||
Internal material | SUS 304 stainless steel | ||||||||||||||
Insulation material | High density polyurethane foam + glass wool | ||||||||||||||
Control System | 7-inch touch screen, Chinese and English display, 120 sets of programs, 1200 segments, all cycles 99 times, partial cycles 99 times, temperature 0.1%of FS±1digit Humidity: 0.1%of FS±1digit, temperature pt-100, humidity: pt- 100or 5V DCV; communication USB or RS485 (other communication negotiation) | ||||||||||||||
The refrigerant | R404/R23 (environmental refrigerant) | ||||||||||||||
cooling system | Semi-closed two-stage compressor (water-cooled) / fully enclosed double-stage compressor (air-cooled) | ||||||||||||||
Safety device | 1. Compressor overpressure, overheating, overcurrent protection; 2 refrigerant high voltage protection switch; 3. fault alarm system; 4. thermal storage high temperature cold storage low temperature protection; 5. electronic alarm; 6. Water shortage alarm protection (water cooling); 7. No fuse switch; 8. Power phase sequence protection; 9. Test chamber temperature protection | ||||||||||||||
Standard accessories | Insulated glass viewing window, two sample holders, measuring hole diameter 50mm*1, power cord, manual | ||||||||||||||
power supply | AC380V 50HZ; three-phase four-wire + ground wire | ||||||||||||||
Controller | Korea TECH Sanyuan; / Taitong TATO | ||||||||||||||
compressor | France Bitzer BITZER compressor / France Taikang TECUMSEH compressor / Germany GEA blog compressor |